Key elements include:
A red "SET" button for settings.
Green buttons with up and down arrows, possibly for navigation or adjustments.
Labels such as "RCT," "BCT," which could refer to current transformers for different phases.
A range indicated as "3 - 50A," suggesting the current measurement capability (likely between 3 and 50 amperes).
A range "0-999M," possibly related to time or another measurement unit.
Operating Voltage 300V to 500V:
This indicates that the system operates within a voltage range of 300V to 500V. Any voltage outside this range may cause the system to malfunction or shut down for safety reasons.
This appears to be a device used in electrical engineering for monitoring or controlling power, current, or other related parameters.
Here is an explanation of each point:
1. Od On Delay Setting (0999 sec):
Controls the delay time before the system turns on after receiving a start signal. It can be set between 0 and 999 seconds.
2. Dt R2 Open Time Setting (225 sec):
This adjusts the duration for which Relay 2 remains open (disconnected) after being activated, with a time range of 2 to 25 seconds.
3. Td Trip Delay Setting (320 sec):
Sets the delay before the system trips (shuts down) after detecting an overload or fault. It can be adjusted between 3 and 20 seconds.
4. O3 3P Overload Setting (350 Amps):
This setting controls the overload current threshold for a threephase system. It allows you to set the maximum allowable current from 3 to 50 amps, beyond which the system trips.
5. D3 3P Dry Run Setting (049.5 Amps):
Sets the current limit for detecting a dry run condition (when the pump or motor is running without load) in a threephase system. If the current falls below the set value (0 to 49.5 amps), the system will stop.
6. O2 All Ph Overload Setting:
This adjusts the overload protection for all phases of the system. It ensures that all phases are protected from excessive current draw.
7. D2 All Ph Dry Run Setting:
This setting is for detecting dry run conditions across all phases. If the current across all phases drops below the set threshold, the system will shut down to prevent damage.
8. Hv High Voltage Cut Setting:
This setting allows you to define the voltage limit at which the system will shut off to prevent damage from high voltage. If the voltage exceeds this set point, the system will cut power.
9. Lv Low Voltage Cut Setting:
Similar to the high voltage setting, this adjusts the threshold for low voltage protection. If the voltage drops below this limit, the system will shut down to avoid undervoltage damage.
10. On On Time Setting (0999 Min):
This sets the duration for which the system remains operational (on) before switching off. You can adjust the time between 0 to 999 minutes.
11. Of Off Time Setting (0999):
Adjusts how long the system remains off before it can restart. It allows setting a delay in the off period from 0 to 999 seconds or minutes (depending on the system configuration).
12. Rd Reset Dry Run (1 Auto, 0 Manual):
Controls whether the system will reset automatically (1) after detecting a dry run (when the system operates without load, such as a pump running without water) or requires manual resetting (0).
13. rt Reset Off Delay (1 Auto, 0 Manual):
Similar to the dry run reset, this setting determines if the system should automatically reset (1) after an off delay or require manual intervention (0) before restarting after a delay.
Potp (Power Trip):
This is a notification about power trip conditions. It indicates that an interruption in the current (amps) has caused a power trip (Potp), which requires addressing the fault condition.
These settings provide control over voltage protection, timing of operation and shutoff, and the behavior of the system in dry run or power interruption scenarios.
Each of these settings provides precise control and protection for the system's operation, ensuring it runs safely and efficiently.