The ADOC is a sophisticated digital motor protection unit operating at 300-450V

 This appears to be an ADOC digital control unit for motor/pump applications. Here are the key specifications and features:

Operating Parameters:

- Voltage range: 300V to 450V

- Model: ADOC-23 (317*2409*1310)

- Configurable for 2-phase and 3-phase systems


Main Functions:

1. Timing Controls:

- Auto Time: 20-999 seconds

- Trip Delay: 3-20 seconds

- On/Off Time settings up to 999 minutes

2. Protection Features:

- 3-phase overload protection (3-40 Amps)

- 2-phase overload protection (4-50 Amps)

- Dryrun protection for both 2P (0-49 Amps) and 3P (0-39 Amps)

- Surge protection built-in

- Voltage difference monitoring

3. Interface:

- Digital display

- SET, UP, DOWN, and ENT/RST buttons

- Manual/Auto operation switch

- Phase selection (3PH/ALL PH)

- Status indicators for R,Y,B phases

4. Advanced Features:

- Auto/Manual reset options

- Float switch compatibility

- Real-time current monitoring

- Power trip detection

- Automatic sequence reversal capability


Connection terminals include inputs for phases (R,Y,B), control signals (CO, Ra, Ya), and auxiliary connections (+12V, FLT, R1, R2).

Button Functions on ADOC:


1. SET Button (Red)

- Enters programming mode

- Confirms parameter selections

- Used to navigate through settings menu


2. UP Arrow (Green)

- Increases parameter values

- Navigates up through menu options

- Selects higher range settings


3. DOWN Arrow (Green)

- Decreases parameter values

- Navigates down through menu options

- Selects lower range settings


4. ENT/RST (Red)

- ENT: Confirms and saves settings

- RST: Resets alarms and fault conditions

- Long press for system reset


5. Manual/Auto Switch

- MAN: Manual operation control

- AUTO: Automated operation based on settings


6. Phase Selection Switch

- 3PH: Three-phase operation mode

- ALL PH: All phase monitoring mode


Parameters Adjustable via Buttons:

- Auto Time (20-999 sec)

- Trip Delay (3-20 sec)

- Overload settings (2P/3P)

- Dryrun protection values

- On/Off timing (999 min)

- Float switch settings

- Voltage difference thresholds


1. At - Auto Time (20-999 Sec)

2. dt - R2 Open Time (2-25 Sec)

3. td - Trip Delay (3-20 sec)

4. o3 - Overload 3P (3-40 Amps)

5. d3 - Dryrun 3P (0-39 Amps)

6. o2 - Overload 2P (4-50 Amps)

7. d2 - Dryrun 2P (0-49 Amps)

8. H3 - High Vol 3Ph Set

9. L3 - Low Vol 3Ph Set

10. H2 - High Vol 2Ph Set

11. L2 - Low Vol 2Ph Set

12. Ud - Voltage Diff Set

13. on - On Time (999 Min)

14. oF - Off Time (999 Min)

15. FL - Float (1-0)


Additional settings:

- rd: Dryrun Reset (1-Auto, 0-Manual)

- rf: Off Delay Reset (1-Auto, 0-Manual)


The ADOC is a sophisticated digital motor protection unit operating at 300-450V for both 2-phase and 3-phase systems. It features comprehensive protection against overload, dryrun, and voltage fluctuations, with adjustable timing controls. The unit incorporates surge protection, real-time monitoring, and automatic sequence reversal, making it ideal for industrial pump and motor applications. Its digital interface allows precise parameter adjustment through a user-friendly control panel.


"This Content Sponsored by Buymote Shopping app

BuyMote E-Shopping Application is One of the Online Shopping App

Now Available on Play Store & App Store (Buymote E-Shopping)

Click Below Link and Install Application: https://buymote.shop/links/0f5993744a9213079a6b53e8

Sponsor Content: #buymote #buymoteeshopping #buymoteonline #buymoteshopping #buymoteapplication"

Post a Comment

Previous Post Next Post